![Hofmann Snap-on Y2k Скачать руководство пользователя страница 97](http://html.mh-extra.com/html/hofmann/snap-on-y2k/snap-on-y2k_service-manual_2144281097.webp)
Seite 97 von 99
C111 Measure First harmonic of the belt (b9450 / b9460)
Displayed on selection:
A scrolling display appears in the left display panel.
Step 1 options:
Tap the belt (with a weight calipers for example). The balancer will beep to confirm that measuring has
started. After 2 – 3 seconds a second beep indicates the end of the measurement and the frequency is
displayed in the right display panel. If no harmonic frequency was detected, "Err" is displayed. The
operator can repeat the test as often as required. The test is started automatically when the belt is
tapped.
The frequency is displayed in Hz from 100 – 300 Hz.
18. Factory Configuration Procedure
Perform service codes in the following order;
1. C47
2. C80
3. C81 (b9460 only)
4. C82 (b9460 only)
5. C83
6. C84
7. C88
The machine is now ready for use.