![Hofmann Snap-on Y2k Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/hofmann/snap-on-y2k/snap-on-y2k_service-manual_2144281070.webp)
Seite 70 von 99
Weight Placement Quick Mode
Holding down the weight placement key for 2 seconds results in a beep being generated and the weight
placement selection mode being toggled between standard (the default) and quick mode. In quick mode
the weight placement key cycles through NORMAL, HWM1 and HWM2 modes only. Upon machine power-
on the selection mode active prior to power-down is restored.
3. Balancing Results Recalculation
Whenever possible, the balancing results displayed are recalculated and re-displayed following a change
to the underlying data (wheel rim data, balancing run raw data). A recalculation may change the
magnitude of the results displayed in the display panels. It also causes the weight bars to be updated.
Results are recalculated and displayed;
•
After a measuring run.
•
Whenever rim data is changed after a measuring run has been performed.
•
Whenever the weight placement mode is changed after a measuring run has been performed.
The HWM modes are designed to enable greater accuracy by allowing the exact correction
plane offsets to be entered (bypassing wheel type based estimates). For this reason
recalculations are performed as follows for HWM;
•
After a measuring run, only if the two weight offsets have been entered and the rim diameter
is within HWM specific limits (greater than 305 for hwm1 and hwm2 (12")).
•
Whenever rim data (diameter only) is changed if a measuring run has been performed and
the weight offsets have been entered.
B9460 Specific Features
Rim data cannot be entered manually during HWM modes with the B9460. This is because
the machine has a 2D inner sape which enters both offset and diameter. Diameter is entered
manually for the B9000 and B9460.
•
Whenever the weight offsets are changed after a measuring run has been performed and the
rim diameter is within HWM specific limits (greater than 305 for hwm1 and hwm2 (12")).
B9460 Specific Features
There is no HWM minimum diameter limit for the B9460. The diameter is limited
mechanically by what the user can enter using the gauge arm.
Содержание Snap-on Y2k
Страница 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Страница 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Страница 10: ...S S M Fig 12 Two systems arranged one above the other with a parallel pair of springs Seite 10 von 99 ...
Страница 32: ......
Страница 35: ...Seite 35 von 99 ...
Страница 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Страница 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...