Seite 43 von 99
18. Check home position of right SAPE
E4
Affected models
: Models with 3D-P-SAPE
Service Codes
: C82 to calibrate SAPE
Outer SAPE gauge arm not in home position.
Re-place SAPE gauge arm in home position and press STOP or ESC key to continue.
19. Disable right SAPE
E93
Affected models
: Models with 3D-P-SAPE
Service Codes
: C82 to calibrate SAPE
During the second attempt the outer SAPE gauge arm was again not re-placed to home position. Outer
SAPE gauge arms are turned off. Wait for 5 seconds, or press STOP or ESC key to continue.
20. Check
calibration
E901
Affected models
: All models
Service Codes
: C80, C81, C82, C83, C84, C88, C90
Machine was not calibrated. For calibration the following calibration codes will have to be carried out in
the sequence as given below:
C80 – Calibration of inner SAPE gauge arm
C81 – Measurement of flange to zero plane distance
C82 – Calibration of outer gauge arm
C83 – Basic calibration of vibratory system
C84 – Measurement of residual main shaft unbalance
C88 – Adjustment of 12 h position
C90 – Saving calibration data
21. Power clamp service interval expired
E93
Affected models
: Models with power clamp
Service Codes
: All codes available for the model
Содержание Snap-on Y2k
Страница 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Страница 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Страница 10: ...S S M Fig 12 Two systems arranged one above the other with a parallel pair of springs Seite 10 von 99 ...
Страница 32: ......
Страница 35: ...Seite 35 von 99 ...
Страница 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Страница 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...