No
Beep sequence
Description
27
L L 7S
Optimisation module
1. Persistent object not available
28
L L 8S
Counters
1. Persistent object not available
30 3L
Extensions:
- keyboard/display, SAPE, brake, motor
1. Persistent object not available
2. Resource not available (timer)
31
3L S
Extensions:
- Drive system
1. Persistent object not available
2. Resource not available (timer)
32
3L S S
Extensions:
- Measurement control
1. Persistent object not available
2. Resource not available (timer)
33
3L S S S
Initialisation of the supervisor program.
Possible faults:
1. Resource not available (timer)
- D - Pause between the cycles
P3
: 3 seconds pause
Example:
* * P0.5
S P1
5S
P3
* * P0.5
2 init beeps with half
a second pause after
One short beep and a
one second pause
5 short beeps
3 seconds pause
NEXT cycle ...
-> Error during initialisation of the persistent objects. e.g. the opto-electronic board is not connected.
Содержание Snap-on Y2k
Страница 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Страница 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Страница 10: ...S S M Fig 12 Two systems arranged one above the other with a parallel pair of springs Seite 10 von 99 ...
Страница 32: ......
Страница 35: ...Seite 35 von 99 ...
Страница 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Страница 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...