Seite 42 von 99
Hardware test - 5V line
14.3
Affected models : All models
Service Codes
: C110 to heck 5V voltage.
C 1 0 8 1 0
C 1 0 8 1 1
If the 5V voltage is below or above a limit the error code is displayed.
Please refer to chapter 0
Hardware test - Current of optoelectronic LED
14.4
Affected models : All models
Service Codes
: C75, AdC1 to check LED
C 1 0 7 0 5
C 1 0 7 0 6
C 1 0 7 0 7
C 1 0 7 0 8
If the current / voltage is below or above a limit the error code is displayed.
Please refer to chapter 0
Hardware test - Transducer signals
14.5
Affected models : All models
Service Codes
: C103/C104 to check transimpedance and signal
amplifiers and transducer values.
C 1 0 4 1 0
C 1 0 4 2 0
C 1 0 4 3 0
If no signals from the transducers are detected the error code is displayed.
Please refer to chapter 0
Hardware test - Auto stop system
14.6
Affected models : Models with auto stop system
Service Codes
: C75, Adc21 to check voltage on capacitor of
the auto stop system.
C 1 0 3 8 0
C 1 0 3 8 1
C 1 0 3 8 2
C 1 0 3 8 3
If the voltage is below or above a limit or the recharging time is above a limit the error code is displayed.
Please refer to chapter 0
15. Hardware test disturbed
H 82
Affected models
: All models
Service Codes
: All codes available for the model
A self test was disturbed (e.g. wheel was rotated during the transducer test)
The code is read out for 3 seconds, then measurement is repeated (10 times maximum), or aborted using the
STOP or ESC key.
16. Check home position of left SAPE
E3
Affected models
: Models with 1D-, 2D-SAPE or geodata
Service Codes
: C80 (& C81) to calibrate SAPE
C92 to check distance and diameter of actual calibration
Inner SAPE gauge arm not in home position.
Re-place SAPE gauge arm in home position and press STOP or ESC key to continue.
17. Disable
left
SAPE
E92
Affected models
: Models with 1D-, 2D-SAPE or geodata
Service Codes
: C80 (& C81) to calibrate SAPE
C92 to check distance and diameter of actual calibration
During the second attempt the inner SAPE gauge arm was again not re-placed to home position. Inner and
outer SAPE gauge arms are turned off. Wait for 5 seconds, or press STOP or ESC key to continue.
Содержание Snap-on Y2k
Страница 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Страница 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Страница 10: ...S S M Fig 12 Two systems arranged one above the other with a parallel pair of springs Seite 10 von 99 ...
Страница 32: ......
Страница 35: ...Seite 35 von 99 ...
Страница 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Страница 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...