![Hofmann Snap-on Y2k Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/hofmann/snap-on-y2k/snap-on-y2k_service-manual_2144281059.webp)
Seite 59 von 99
C
Description
CRT,HNA,
HWT
GS
JBEG
44
45
46
Selecting the private brand
NA
47
Select machine model
S S S
48
Download of application to FLASH memory. (Needs special software version)
Please refer to chapter 0 "In Field Reprogramming of Balancer" for details how
to program the balancer.
(S)
49
50
Indication of voltage on distance analogue input
NA
51
Indication of voltage on diameter analogue input
NA
52
Indication of voltage on width analogue input
NA
53
Display test - Only balancers with digital display
S
54
Checking the incremental encoder on the main shaft
S
55
Indication the line voltage
S
56
Indication of the circuit state of the wheel guard switch
S
57
Indication of temperature
S
58
Indication of balancing calculation values
59
Indication of the residual unbalance compensated for using code C84
S
60
Motor
: Indication of RPM of main shaft
Hand-spin : Measure amount of measuring turns (C84 simulation)
S
61
Indication of correction values for user calibration
S
62
Indication of angular position [0,360) of unbalance weight.
63
Continuous measurement (with statistics)
S S S
64
Indication of the transducer sensitivity as measured with C code 83
S
65
Indication of phase differences and phase shifts
66
Display calibration values as measured with C code 83 (virtual dimensions)
S S S
67
Display phase stability of the vibratory system as measured with C code 83
S S S
68
Indication of time to reach measurement speed during last measurement run
69
Successive measurement runs with pauses and statistics
S 2.2
S
S
70
Test light for inner rim.
NA
71
72
Measurement of angular deviation
S S S
73
Indication of delay of solenoid brake
74
Indication of position counter and basic incremental encoder test
S S S
75
Display values from AD converter
S S S
76
Indication of the voltages used by the 2 step motor control
S S S
4.19
77
78
Restarting the program with self test
79
80
Calibration of the inner SAPE gauge arm and the AutoStopSystem
S S S
81
Measuring the adaptor flange and the zero plane.
S S S
82
Calibration of the outer SAPE.
S S S
83
Calibration of the unbalance measurement with wheel/test rotor.
S S S
84
Compensation of unbalance of main shaft
S S S
85
Copy content of serial EEPROM (EEP) from micro-controller EEP to
incremental encoder EEP.
S S S
86
Copy content of serial EEPROM (EEP) from incremental encoder EEP to
micro-controller EEP.
S S S
87
88
Calibration of the 12 o'clock position for fitting position of weights
S S S
89
90
Saving the adjustments data in the PO's
(CRT, HNA, HWT only)
S
91
92
Display of actual distance and diameter of inner SAPE/geodata
S
93
Indication of line frequency.
94
95
Test of serial line (RS-232-E).
Содержание Snap-on Y2k
Страница 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Страница 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Страница 10: ...S S M Fig 12 Two systems arranged one above the other with a parallel pair of springs Seite 10 von 99 ...
Страница 32: ......
Страница 35: ...Seite 35 von 99 ...
Страница 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Страница 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...