C69 Continuous Measuring Runs With Pauses (b9450 / B9460 only).
Displayed on selection:
The digit "1" in the left display to indicate the step number. The first pause value in the right display.
Step 1 options:
Select the first pause period in seconds using the PLUS and MINUS keys. Confirm your selection using the
RETURN key.
Step 2 options:
The digit "2" in the left display to indicate the step number. The second pause value in the right display.
Select the second pause period in seconds using the PLUS and MINUS keys. Confirm your selection using
the RETURN key.
Step 3 options:
The digit "3" in the left display to indicate the step number.
Lower the hood to begin the measuring runs. The runs will continue to execute and results will be
displayed in grams. There will be a pause between each run and the balancer will beep repeatedly to
indicate that C69 is in progress.
Raise the hood at any stage to exit the code.