10 Software »Motion Manager«
Operating manual mzr-2509 Ex/ mzr-2909 Ex / mzr-4609 Ex / mzr-7209 Ex
Last update: October 2016
Technische Änderungen ohne Vorankündigung vorbehalten.
77
; File:
switchdosage_2909_e3_S.mcl
; Description: Dosage triggered with switch for mzr-2909 Ex
;
Start dosage with switch on digital input 3
;
Fault as error output programmed
; Hardware:
Motion Controller S-HD-KL with switch, Controller MCDC3006S, Interface RS-232
;
; Date:
2012-03-29
; Copyright © 2012, HNP Mikrosysteme GmbH, Parchim
;
; HNP Mikrosysteme GmbH, Juri-Gagarin-Ring 4, 19370 Parchim
; T49(0)3871/451-301, T49(0)3871/451-333
; Email: [email protected], http://www.hnp-mikrosysteme.de
;
; ! ! ! Important ! ! !
;
- Turn the potentiometer on the connection panel into zero position by
;
turning clockwise to the right stop motion device
;
- Then transfer this file with menu command 'Terminal - Transfer configuration file' to the
pump
;
- Save the transferred settings into the EEPROM
;--------------------------------------------------------------------------------------------------------------
; Program sequence
;--------------------------------------------------------------------------------------------------------------
PROGSEQ
;Program start
A1
;Label 1 (program start)
HP4
;Rising edge active and logic level to High for input No. 3
A2
;Label 2
JPT2
;Cycle 2 Low-Pegel on Input 3
HP0
;Falling edge active and logic level to Low for input No. 3
A3
;Label 3
JPT3
;Cycle 3 bis High-Pegel on Input 3
HO
;Set the actual position to 0
LR20000
;Load relative target position (2000 = 1 rev.) <------- Please edit the target
position value !
NP
;Notify Position (wait after "M" until target position is reached)
M
;Move to target position
JMP1
;Jump to the beginning
END
;--------------------------------------------------------------------------------------------------------------
; Configuration
;--------------------------------------------------------------------------------------------------------------
SOR0
;Source For Velocity - Solldrehzahl über Schnittstelle RS-232
CONTMOD
;Continuous Mode - Normalbetrieb
KN246
;Load Speed Constant - Drehzahlkonstante laden [rpm/V]
RM1230
;Load Motor Resistance - Motorwiderstand laden [mOhm]
APL0
;Position Limits - Positionslimits deaktivieren
MOTTYP8
;Motor Type - EC-Motor 3564K024B C
POHOSEQ0
;Power On Homing Sequence - Keine Homing-Sequenze nach dem
Einschalten
ERROUT
;Error Output - Umschalten auf Fehlerausgangsmodus
HP7
;Hard Polarity - alle Eingänge steigende Flanke gültig
HB0
;Hard Blocking - Kein Hard-Blocking
HD0
;Hard Direction - Für alle Endschalter Linkslauf sperren (falls Hard-Blocking
aktiv)
HOSP100
;Load Homing Speed - Homing-Speed auf Rechtslauf mit 100 rpm
SHA0
;Set Home Arming - deaktivieren
SHL0
;Set Hard Limit - deaktivieren
SHN0
;Set Hard Notify - deaktivieren
ADR
;Analog Direction Right - Positive Spannung für Rechtsdrehung
LPC800
;Load Peak Current Limit - Spitzenstrom [mA] laden
LCC600
;Load Continius Current Limit - Dauerstrom [mA] laden
AC550
;Load Command Acceleration - Beschleunigung laden [U/s²]
DEC550
;Load Command Deceleration - Bremsverzögerung laden [U/s²]
I25
;Load Velocity Integral Term - Drehzahlreglerintegralanteil laden
POR2
;Load Velocity Proportional Term - Drehzahlreglerverstärkung laden
PP3
;Load Position Proportional Term - Ladereglerverstärkung laden