10 Software »Motion Manager«
Operation manual mzr-2509 Ex/ mzr-2909 Ex / mzr-4609 Ex / mzr-7209 Ex
68
Technische Änderungen ohne Vorankündigung vorbehalten
Last update: October 2016
For saving of settings of the configuration or program sequence in the onboard
memory (EEPROM) answer the question »Should the EEPSAV command be
carried out and the transferred settings saved?« with »Yes«. At that time the
settings are written to the EEPROM. After switch on/off of the motion
controller settings and program is available.
The delivery volume comprises the standard program
mzr-2509_S.mcl,
mzr-2909_S.mcl,
mzr-4609_S.mcl
,
mzr-7209_S.mcl
and the sample programs
switchdosage_2509_S.mcl
,
switchdosage_2909_S.mcl
,
switchdosage_4609_S.mcl
and
switchdosage_7209_S.mcl
for triggered dosage
with an external switch.
The standard program
mzr-2509_S.mcl
(see Listing 1) is saved at delivery state
of the micro annular gear pump mzr-2509 Ex.
Upon delivery the motion controller is configured with following parameter:
−
Operation mode analogue input, Source for velocity via potentiometer
(Command SOR1)
−
Enable driver (Command EN)
−
Continuous mode (Command CONTMOD)
−
Maximum velocity 4700 U/min (Command SP4700)
−
Maximum peak current 800 mA (Command LPC800)
−
Maximum continuous current 600 mA (Command LCC600)
−
Acceleration 550 U/s² (Command AC550)
−
Fault pin as error output (Command ERROUT)
−
Asynchronous answer (Command ANSW1)
−
Clear program memory with no programs
; File:
mzr-2509_S.mcl
; Description:
Standard mcl-file for micro annular gear pump mzr-2509Ex
;
Speed is controlled by potentiometer of the connection panel
;
Fault as error output program
; Hardware:
Motion Controller S-HD-KL, Steuerung MCDC3006S, Schnittstelle RS-232
;
; Date:
2012-03-29
; Copyright © 2012, HNP Mikrosysteme GmbH, Parchim
;
; HNP Mikrosysteme GmbH, Juri-Gagarin-Ring 4, 19370 Parchim
; T49(0)3871/451-301, T49(0)3871/451-333
; Email [email protected], http://www.hnp-mikrosysteme.de
;
;--------------------------------------------------------------------------------------------------------------
; Configuration Motor
;--------------------------------------------------------------------------------------------------------------
SOR1
;Source For Velocity - Solldrehzahl über Potentiometer
CONTMOD
;Continuous Mode - Normalbetrieb
KN246
;Load Speed Constant - Drehzahlkonstante laden [rpm/V]
RM1230
;Load Motor Resistance - Motorwiderstand laden [mOhm]
APL0
;Position Limits - Positionslimits deaktivieren
MOTTYP8
;Motor Type - EC-Motor 3564K024B C
POHOSEQ0
;Power On Homing Sequence - Keine Homing-Sequenze nach dem
Einschalten
ERROUT
;Error Output - Umschalten auf Fehlerausgangsmodus
HP7
;Hard Polarity - alle Eingänge steigende Flanke gültig
HB0
;Hard Blocking - Kein Hard-Blocking
HD0
;Hard Direction - Für alle Endschalter Linkslauf sperren (falls Hard-Blocking
aktiv)