HV350 Mini Frequency Inverter User Manual
33
DC injection braking
P1.07
DC injection braking
time
0
:
No operation
0.1~60.0s
0
27
+
P1.08
DC injection braking
current
0.0~100.0%(motor rated current)
0
28
+
P1.09
Acc/Dec
mode
selection
0: Linear mode
1
:
reserved
0
29
+
P1.10
Time of S curve‘ s
start part
10.0%~50.0%
20.0%
30
+
P1.11
Time of S curve‘ s
rising part
10.0%~80.0%
60.0%
31
+
P1.12
Restart after power
failure
0: disabled
1: enabled
0
32
+
P1.13
Delay
time
for
restarting after power
failure
0.0~20.0s
2.0
33
+
P1.14
dynamic braking start
voltage
630-710
660
34
P1.15
Rate
of
dynamic
braking
0
:
No dynamic braking
1~100%
90
35
#
P1.16
Action on frequency
lower than lower
frequency limit
0
:
dormancy
1:start, running at lower
frequency limit
2
:
Stop
0
36
+
P1.17
MF key function
0:
No operation
; 1:reverse rotation
0
37
+
P1.18
Stop/reset
Key
function
0:action on keypad control mode
1:action on both keypad and
External
terminal
2:action on both keypad and
communication
0
38
+
P1.19
reserved
1
39
+
P2 Group
Auxiliary function parameters 2
P2.00
Acc time 2
0.1~3600s
20.0
40
#