HV350 Mini Frequency Inverter User Manual
37
P5.08
reserved
104
+
P5.09
reserved
105
+
P5.10
reserved
106
+
P6 Group I/O parameters
P6.00
FWD/REV mode
0: Two-line operation mode 1
1: Two-line operation mode 2
2: 3-line operation mode 1
3: 3-line operation mode 2
0
107
+
P6.01
Up/down rate
0.10~99.99Hz/s
1.00
108
#
P6.02
Definition of input
terminal X1
0 No function
1: FWD
2: REV
3: External reset
4: Jog FWD
5: Jog REV
6: Multi-frequency 1
7: Multi-frequency 2
8: Multi-frequency 3
9: Multi-frequency 4
10: Terminals for selecting Acc/Dec time 1
11: Terminals for selecting Acc/Dec time 2
12: Normally open terminal for inputting
external fault
13: Normally close terminal for inputting
external fault
14: Frequency increase command
15: Frequency decrease command
16: Free run to stop
17: Three-wire control
18: switch of speed given mode
19
:
Reset terminal for program operation
20: Start traverse operation
21
:
pause traverse operation
22
:
DC braking command
23
:
Acc/Dec disabled command
24
:
switch between panel control mode and
external terminal control mode
1
109
+
P6.03
Definition of input
terminal X2
2
110
+
P6.04
Definition of input
terminal X3
3
111
+
P6.05
Definition of input
terminal X4
4
112
+
P6.06
Definition of input
terminal X5
5
113
+
P6.07
Definition of input
terminal X6
16
114
+
P6.08
reserved
0
115
+