HV350 Mini Frequency Inverter User Manual
85
P8.00/P8.01
Drive state
Description
0
Running
frequency/speed
0~ highest running frequency/speed
1
Frequency
setting/speed
0~ highest running frequency/speed
2
Output current
0~ 2
×
rated current
3
Output voltage
0~+200% rated voltage
4
Output torque
-200%
~
+200% rated torque current
5
PI reference
0
~
10V
6
PI feedback
0
~
10V
7
Bus voltage
0-800V
8
Analog input AI1
0-10V
9
Analog input AI2
0-10V
p8.02 Minimum AO1
Setting range:0.00
~
100.0%
p8.03 Minimum value corresponding to F8.02
Setting range:0.00
~
100.0%
p8.04 Maximum AO1
Setting range:0.00
~
100.0%
p8.05 Maximum value corresponding to F8.04 Setting range:0.00
~
100.0%
This function code is used to setup maximum/minimum value of analog output
signal (0~10V), and the relationship between these values and P8.00 is shown in
Fig. 6-27 and 6-28.
0 Minimum value
(F8.02)
Corresponding to
the maximum
(F8.05)
AO1 Output signal
Output(F8.00)
Maximum value
(F8.04)
Corresponding to the minimum
value(F8.03)
Fig. 6-27 Relationship between maximum/minimum AO1 and F8.00