HV350 Mini Frequency Inverter User Manual
38
25
:
switch between panel control mode and
communication control mode
26: Counter trig signal
27: Counter reset signal
28: PID dormancy waking up
29
:switch between PID positive mode and
negative mode
30
:
emergence stop
P6.09
Programmable relay 1
0: No function
1: Drive ready
2: Drive running signal 1
3: Drive running signal 1
4: Frequency arriving signal
5: Frequency detection threshold 1
6: Frequency detection threshold
2
7: High limit frequency arriving
8: Low limit frequency arriving
9: Overload signal
10: Over voltage stall
11: Over current stall
12: External stopping command
13: Preset counting value arriving
14: Specified counting value arriving
15: Low voltage lockup signal
16: Overload pre-alarm
17: Drive failure signal
18: Zero speed running
19
:
end signal of stage of program operation
20
:
end signal of cycle of program operation
17
116
+
P6.10
Output terminal Y1
definition
1
117
+
P6.11
Frequency
arriving
width
0.00~10.00Hz
0.00
118
#
P6.12
FDT1 level
0.00~400.0 Hz
50.00
119
#
P6.13
FDT1 lag
0.00~10.00Hz
0.00
120
#
P6.14
FDT2 level
0.00~400.0 Hz
25.00
121
#
P6.15
FDT2 lag
0.00~10.00Hz
0.00
122
#
P6.16
Preset value arriving
0~9999
0
123
+
P6.17
Specified
value
0~9999
0
124
+