Configuration
When power is applied the gateway will run the following startup sequence:
1.
Applying TCP/IP network settings using DHCP or static configuration
2.
Initial generation of SSL device keys (may take some time on first startup)
3.
Setting system time via SNTP
4.
Starting system services
5.
Starting the main application
The Anybus M-Bus to Modbus-TCP gateway is normally configured using the web interface,
which gives access to all device parameters, meter configuration, and services.
The gateway can also be configured by editing and uploading configuration files directly to the
device using FTP. See
Advanced Configuration, p. 37
.
4.1
Web Interface Login
The first time you access the web interface you will be automatically logged in as the default
username (web). You can also log in as the default user manually by clicking
Default Login
on
the login screen. The default user only has read access.
If the default user has been disabled in the configuration, you must enter a valid username and
password and click
Login
.
Fig. 4
Login window
Default usernames and passwords
Username
Password
Description
admin
admin
Administrator user with root access, allows full access to all services (HTTP,
FTP, flash update, IP configuration).
web
web
Default user for the web interface. Allows write access to the web interface.
If a user with this name and password exists, the web server will automatically
log in with these credentials when accessed.
ftp
ftp
User for FTP access to the log directory of the gateway (C:/log/)
If you are logged in with write access you should always log out after finishing the
configuration, as only one user with write access can be logged in at a time. If your
session stays active, other users will not be able to log in with write access.