![HMF Scanreco G2 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/hmf/scanreco-g2/scanreco-g2_manual_2141494051.webp)
Scanreco G2 radio remote control system
51
HMF Technical Service Department
Rev.:
20-13
Error codes
Comment
RCL
display
LED display
in G2
Error code in
RCL 5300
black box
Error
description
Cause
Remedy
170
08.04
0804
CAN PDO - error
in message
length.
The length of the
CAN data packet is
too long
The system carries out
automatic reset. Restart
the system.
170
08.05
0805
CAN PDO - error
in message
length.
The length of the
CAN data packet is
too short
The system carries out
automatic reset. Restart
the system.
170
08.06
0806
Error in the
transmission of
CAN messages.
There are too many
CAN data packets.
The system carries out
automatic reset.
Check the CAN
connections.
Check the controller
connected to the CAN
output (if fitted).
172
10.00
1000
Failure in the
stop button.
The failure is
transmitted from the
remote control box.
Error in the signal
from the stop button
of the remote control
box.
The system carries out
automatic reset again.
Check the stop button for
faults.
173
11.00
1100
A control lever is
activated when
starting up from
the remote
control
box.
The error is
transmitted from the
remote control box.
An analogue input
signal is high when
starting up.
The system will not
automatically carry out
reset but is in safe mode.
Check that all remote
control levers are in
neutral position and do
not give an analogue
signal. Restart the remote
control box.
174
13.00
1300
There is not a
redundant signal
from a control
lever.
There is a signal
which is not
permitted from an
analogue input from
the remote control
box.
The system carries out
automatic reset again.
Troubleshoot with the
remote control box in
TEST MODE.
175
14.01
1401
ID-coding has not
been carried out.
The ID-coding or the
parameter settings
have not been
approved by the
system.
The system carries out
automatic reset again.
Repeat downloading the
ID-code.
170
14.02
1402
The system does
not support the
value of a
parameter.
A parameter has
been incorrectly set
up.
The system carries out
automatic reset again.
171
15.xy
15xy
Short circuit on
an analogue
output:
X=channel 1-16
Y=direction A or
B.
The third sequence
on the LED display
indicates which
output has an error.
1A, 1B……
The system carries out
automatic reset. Check all
analogue output
terminals. Remove the
plug and restart the
system.
-
16.xy
----
Open analogue
output
X=channel 1-16
Y=direction A or
B.
The third sequence
on the LED display
indicates which
output has an error.
1A, 1B……
The system carries out
automatic reset. Check all
analogue output
terminals. Remove the
plug and restart the
system.