Scanreco G2 radio remote control system
10
HMF Technical Service Department
Rev.:
20-13
•
Penetrate the membranes of the cable lead-ins with for instance a small screwdriver. The fitting
must be tight when pulling through the cable to ensure a tight system.
•
Fit a cable relief on the inside.
•
Cover all visible metallic parts on wires and in ground connections with water repellent lubricant.
•
Position the cables as shown in the picture.
In case of welding on the vehicle
Before carrying out any welding on the vehicle, all electric connections for external components
and power supply (both + and -) must be dismounted.
In case of recharging by means of a boost starter
Remove the cable for the power supply, if the battery of the vehicle is discharged, and
connect a “boost starter” to start the engine. Any kind of too high charging voltage (power
supply) or voltage peaks entail the risk of overloading and in the worst case damaging the
electronic safety system.