![HMF Scanreco G2 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/hmf/scanreco-g2/scanreco-g2_manual_2141494015.webp)
Scanreco G2 radio remote control system
15
HMF Technical Service Department
Rev.:
20-13
Menu item in CGW
5355
Description of functions and parameters
1.1.1.1.1.25.2.5
Source
Each PWM output can be controlled by an optional output signal - operated from the remote
control box - in the
Source
menu. The output signal may be for a crane function, stabilizer
function or extra function.
The following outputs can be activated:
1.1.1.1.1.25.2.5-
PWM 1A, K1.1 - PWM 4A, K1.13 and
1.1.1.1.1.25.2.5-
PWM 5A, K3.1 - PWM 8A, K3.13
1.1.1.1.1.25.2.5-
PWM 1B, K1.3 - PWM 4B, K1.15 and
1.1.1.1.1.25.2.5-
PWM 5B, K3.3 - PWM 8B, K3.15
1.1.1.1.1.25.2.6
Source Setup
In
Source Setup
it is possible for each PWM output signal in
Source
to select (SET
and arrow down) between the following signal types:
1. None
2. A Prop.
Operation from a remote control lever.
A proportional signal for a NEM activation for oil flow to the A port on a crane
control valve function (a crane function selected in
Source
) or the A port of
another type of proportional control valve (an Ex. 1-16* function selected in
Source
).
3. B Prop.
Operation from a remote control lever.
A proportional signal for a NEM activation for oil flow to the B port on a crane
control valve function (a crane function selected in
Source
) or the B port of
another type of proportional control valve (an Ex. 1-16* function selected in
Source
).
4. A Dig.
Operation from a remote control lever.
A digital signal for an ON-OFF activation for oil flow to the A port on a stabilizer
control valve function (an STB 1-16 function selected in
Source
) or another type
of ON-OFF control valve (an Ex. 1-16* function selected in
Source
).
5. B Dig.
Operation from a remote control lever.
A digital signal for an ON-OFF activation for oil flow to the B port on a stabilizer
control valve function (an STB 1-16 function selected in
Source
) or another type
of ON-OFF control valve (an Ex. 1-16* function selected in
Source
).
6. A Hold
Operation from a remote control lever.
A digital holding signal for an ON-OFF activation for oil flow to the A port on a
control valve function, which is to be kept activated (an Ex. 1-16* function
selected in
Source
).
7. B Hold
Operation from a remote control lever.
A digital holding signal for an ON-OFF activation for oil flow to the B port on a
control valve function, which is to be kept activated (an Ex. 1-16* function
selected in
Source
).
8. Digital
Operation from a tumbler switch or push button on the remote control box.
An ordinary digital output signal for a function selected in
Source
.
9. Digital hold
Operation from a tumbler switch or push button on the remote control box.
An ordinary digital holding signal for a function selected in
Source
.
*) The Ex. 1-16 signals can be used for control of the control valves for optional
extras. They can be used both in crane mode (e.g. Ex. 1-4) and stabilizer mode (for
example Ex. 8-16). However, the same Ex.-signal cannot be used both in crane
mode and stabilizer mode.
The signals are by default proportional and come from an activation of the remote
control levers on the remote control box.
The signals can also be digital (or digital with holding function) so that the remote
control levers can be used "as push buttons" or "tumbler switches" for activating
and deactivating an output terminal.