Scanreco G2 radio remote control system
26
HMF Technical Service Department
Rev.:
20-13
Menu item in CGW 5355
Configuration
Description of the function
1.1.1.1.3.11 - Display
ENT
- Activate the feature -
Display
- if the remote control
box has a display fitted.
1.1.1.1.3.19 - PVED
ENT
- Activate the feature
PVED
.
1.2.2.1 - Valves
ENT
- Each single PVED electric activation, which is fitted
on the control valve, is programmed for the respective
crane functions.
1.1.1.1.3.9 - Engine
ENT
- Activate the feature
Engine
.
1.1.1.1.1.9 - Engine
ENT
- Mark the required engine control functions.
SET, arrow up
- A cross (ticked off) indicates that the function has
been selected.
1.1.1.1.2.2.4 - PVSK-PVEO-DI
SET, arrow up
- Activate the PVEO electric activation for the PVSK
section of the PVG 32 control valve. A cross (ticked
off) indicates that the function has been selected.
1.1.1.1.2.3.2.6 - Wire sec
ENT
- Configure the Wire Security signal from the G2 radio
controller as input signal to the RCL 5300.
1.1.1.1.2.3.2.6.1 - Module
SET, select
RCL 5300B
- Input signal to the RCL 5300B processor.
1.1.1.1.2.3.2.6.2 -
Input, select
K384 (D4)
- Configuration of the input terminal K384.
1.1.1.1.2.3.2.6.3 -
Invert
- The signal is not to be inverted (not ticked off).
1.1.1.1.2.3.2.6.4 -
NPN
- The signal must be PNP (not ticked off).
1.1.1.1.2.4.1.1 - O1 K397
ENT
- Configuration of the output signal for activation of
the PVEO-DI electric activation on the PVSK-module.
1.1.1.1.2.4.1.1.1 - Min current
SET, type 0
- Set the minimum current at 0 mA.
1.1.1.1.2.4.1.1.2 - Max current
SET, type 2000
- Set the maximum current at 2000 mA.
1.1.1.1.2.4.1.1.3 - Signal
SET, select
PVSK DMP
- Output signal for activation of the PVEO-DI electric
activation - crane mode
1.1.1.1.2.4.1.2 - O1 K395
ENT
- Configuration of the output signal for activation of
the PVEO-DI electric activation on the PVSK-module.
1.1.1.1.2.4.1.2.1 - Min current
SET, type 0
- Set the minimum current at 0 mA.
1.1.1.1.2.4.1.2.2 - Max current
SET, type 2000
- Set the maximum current at 2000 mA.
1.1.1.1.2.4.1.2.3 - Signal
SET, select
PVSK SHIFT
- Output signal for activation of the PVEO-DI electric
activation - stabilizer mode.
1.1.1.1.2.3.2.25 - PVSK dump
ENT
- Configuration of the input signal from the PVEO-DI
electric activation on the PVSK-module.
1.1.1.1.2.3.2.25.1 - Module
SET, select
RCL 5300B
- Input signal (feedback) to the RCL 5300B processor
informing that the PVSK-module is moved towards
crane mode.
1.1.1.1.2.3.2.25.2 -
Input, select
K387
- Configuration of the input terminal K387.
1.1.1.1.2.3.2.25.3 -
Invert
- The signal is not to be inverted (not ticked off).
1.1.1.1.2.3.2.25.4 -
NPN
- The signal must be PNP (not ticked off).
1.1.1.1.2.3.2.26 - PVSK shift
ENT
- Configuration of the input signal from the PVEO-DI
electric activation on the PVSK-module.
1.1.1.1.2.3.2.26.1 - Module
SET, select
RCL 5300B
- Input signal to the RCL 5300B processor informing
that the PVSK-module is moved towards stabilizer
mode.
1.1.1.1.2.3.2.26.2
Input, select
- Configuration of the input terminal K388.
1.1.1.1.2.3.2.26.3
Invert
- The signal is not to be inverted (not ticked off).
1.1.1.1.2.3.2.26.4
NPN
- The signal must be PNP (not ticked off).
1.1.1.1.2.7 - Valve function
ENT
- Configuration of the crane functions included in the
current crane control valve.
1.1.1.1.2.7.1 - Primary function
ENT
- Select the first of two possible configurations.
1.1.1.1.2.7.1.1 - Valve 1
SET, arrow down
- Select the first crane function (e.g. Slew), ENT.
1.1.1.1.2.7.1.1 - Valve 2
SET, arrow down
- Select the second crane function (e.g. Boom), ENT.
Etc.
SET, arrow down
- Select all relevant crane functions.