Setting up of output signals by means of the CGW 5355
By means of the CGW 5355 it is possible to select signal sources which activate different output
signals from the Scanreco G2 radio controller or controllers in the RCL 5300 Safety System.
In the table below is indicated each single selectable signal name, the corresponding signal
source and a description of the functionality controlled by the signal.
Please note that it is the same set of parameters of signal names that can be selected in the
Output config,
menu 1.1.1.1.2.4 when setting up the output terminals in the RCL 5300 and other
controllers in the CAN network. Therefore there will also appear signal names others than the
ones relating to the Scanreco G2 radio remote control system.
The signal names are indicated in the order in which they appear in the CGW display when
pressing SET on an output in
PWM Mixer - PWM - Source
, menu item 1.1.1.1.1.25.2.5.1-16 and
when pushing the "arrow down" button.
In the table is indicated signal sources from
the remote control levers, tumbler switches
and push buttons on the remote control
box.
Designations of tumbler switches and push
buttons appear from the photo.
Signal name
Signal source
Description of signal
None
No
No signal
OFF
No
Always low signal
ON
Signal from controllers in the RCL
5300 safety system or from the
Scanreco G2 radio controller.
Constant high signal
DMP1
Signal from the RCL 5300
controller.
High signal for dump valve 1 in all
situations where the RCL safety system
allows the crane to work.
DMP2
Signal from the RCL 5300
controller.
High signal for dump valve 2 in all
situations where the RCL safety system
allows the crane to work.
STB SHIFT VALVE
2 x activating the yellow push
button (pos. 7) on the remote
control box or the RCL 5300
indicator panel.
High signal for the change-over valve - oil
flow for crane functions or stabilizer
functions. Change from crane mode to
stabilizer mode.
HDL
Signal from the RCL 5300 safety
system when the load moment of
the crane is less than 90%.
High signal for the HDL valve when the
crane is in crane mode - not HDL.
REGEN BOOM
Activation of the ON push button on
the remote control box.
High signal for the regeneration valve on
the "boom up" function (regeneration),
when the load moment of the crane is less
than 50 %.