Survey of terminals in the radio controller
In the below table we have stated the number of the output terminals and output cables as well as
the signal.
Connection of output cables and the corresponding function can be found in the electric diagrams
for the Scanreco G2 radio remote control system.
Please note: In certain applications the output terminals may be configured for alternative
functions.
Terminals in
K1 socket
Cable Signal
Terminals
in K3
socket
Cable
Signal
Terminals
in K4
socket
Cable Signal
K1.1
1A
PWM +
K3.1
5A
PWM +
K4.1
EX1
ON-OFF 1
K1.2
1A
PWM ÷
K3.2
5A
PWM ÷
K4.2
EX1
ON-OFF 2
K1.3
1B
PWM +
K3.3
5B
PWM +
K4.3
EX1
ON-OFF 3
K1.4
1B
PWM ÷
K3.4
5B
PWM ÷
K4.4
EX1
ON-OFF 4
K1.5
2A
PWM +
K3.5
6A
PWM +
K4.5
EX1
ON-OFF 5
K1.6
2A
PWM ÷
K3.6
6A
PWM ÷
K4.6
EX1
ON-OFF 6
K1.7
2B
PWM +
K3.7
6B
PWM +
K4.7
EX1
GND (÷)
K1.8
2B
PWM ÷
K3.8
6B
PWM ÷
K4.8
EX1
DIG IN 1
K1.9
3A
PWM +
K3.9
7A
PWM +
K4.9
EX1
DIG IN 2
K1.10
3A
PWM ÷
K3.10
7A
PWM ÷
K4.10
EX1
DIG IN 3
K1.11
3B
PWM +
K3.11
7B
PWM +
K4.11
EX1
Input, VDC
K1.12
3B
PWM ÷
K3.12
7B
PWM ÷
K1.13
4A
PWM +
K3.13
8A
PWM +
K1.14
4A
PWM ÷
K3.14
8A
PWM ÷
K1.15
4B
PWM +
K3.15
8B
PWM +
K1.16
4B
PWM ÷
K3.16
8B
PWM ÷
Terminals in
K6 socket
Cable Signal
Terminals
in K7
socket
Cable Signal
Terminals in
K7 socket
Cable Signal
K6.1
EX2
ON-OFF 7
K7.1
RC
12/24 V
K8.1
EX3
CAN High
K6.2
EX2
ON-OFF 8
K7.2
RC
GND (÷)
K8.2
EX3
CAN Low
K6.3
EX2
ON-OFF 9
K7.3
RC
Wire security
K8.3
EX3
CAN ÷
K6.4
EX2
ON-OFF 10
K7.4
RC
DMP ÷
K8.4
EX3
CAN High
K6.5
EX2
GND (÷)
K8.5
EX3
CAN Low
K6.6
EX2
ON-OFF 11
K6.7
EX2
ON-OFF 12
K7.8
EX2
ON-OFF 13
K8.9
EX2
ON-OFF 14
K9.10
EX2
GND (÷)