When the fault monitoring of the radio controller registers an error, and error codes are indicated
as stated above, data with the error code are transmitted to the RCL 5300 controller, saving the
error code in an error log in the black box.
By means of the CGW 5355 service terminal it is possible to read the error code from the black
box.
Example of indication of error codes:
Menu item in CGW 5355 Description
CGW command
1.3
Black box
ENT
1.3.4
Remote log
ENT
Example of error code:
1.3.4.1 - Error 1
171
ENT
1.3.4.1.1 - Date
Date, hour and minute when the error occurred
1.3.4.1.2 - RCL error
171 - Error code as indicated on the RCL 5300 display
1.3.4.1.3 - SRG2 error
0202 - Error code in the LED display in the radio
controller.
1.3.4.2 - 50
The RCL saves up to 50 different error types
In connection with troubleshooting, it is possible by means of the CGW 5355 to read the specific
type of error without having to remove the cover of the radio controller.
In the table below you see the interconnections between the error codes. Furthermore there is an
explanation of the type of error, the reason for the error, if any, as well as what can be done to
remedy the error.
Error codes
Comment
RCL
display
LED display
in G2
Error code in
the RCL 5300
black box
Error
description
Cause
Remedy
170
01.01
0101
Checksum error
in EEPROM
Checksum when
starting up is
incorrect.
The system is in safe
mode. Restart the
system. Please contact
HMF Technical Service.
170
01.02
0102
Checksum error
in FLASH
Checksum in the
FLASH memory is
incorrect.
The system is in safe
mode. Restart the
system. Please contact
HMF Technical Service.
170
01.03
0103
Unstable
execution of
program routines
in the software.
Incorrect data set in
the CAN open
protocol, incorrect
data flow or overflow
on CAN.
The system carries out
automatic reset. Please
contact HMF Technical
Service.
170
01.04
0104
Instability in the
hardware
Error in RAM or
hardware
identification.
The system carries out
automatic reset. Please
contact HMF Technical
Service.