Scanreco G2 radio remote control system
45
HMF Technical Service Department
Rev.:
20-13
Online programming
All kinds of programming of parameters - crane speeds, HDL speeds, direction of crane functions
when operating remote control levers etc. - must be carried out by means of the CGW 5355
service terminal which is connected to the RCL 5300 controller.
On cranes with a Scanreco G2 radio remote control system fitted, which controls PWM electric
modules but where no RCL 5300 controller is included, it is possible to carry out online
programming directly from the remote control box.
In case of proportional control of NEM electric activations on the Hydrocontrol control valve, the
starting and final current must be adjusted for each crane function.
Only in this case, online programming is permitted. A mixture of online adjustment and
adjustment by means of the CGW 5355 will make it impossible to carry out the settings
correctly.
1. Take out the battery from the remote control box.
2. Connect the remote control cable between the remote control box and the radio controller.
3. Test the remote control system by operating the crane from the remote control box via the
remote control cable.
4. Push the stop button on the remote control box.
5. Put the tumbler switch on the radio controller in
OFF
position.
6. Turn/pull out the stop button on the remote control box.
7. Put the tumbler switch on the radio controller in
Remote
position, and within 10 seconds
continue with item 8.
8. Push the
ON
button; the Power LED is turned on.
9. Activate in a fast sequence the
Micro
tumbler switch 10 times to the right, until a long buzzer
signal appears.
The LED display in the radio controller shows ”
Po
” - ”
00
”, and the system is in online
programming mode.
10. Push the
ON
button twice; the LED display shows ”
Po
” - ”
02
”. The minimum starting current is
adjusted here.
11. Activate the remote control lever for a crane function. When the
Micro
tumbler switch is
pushed to the right, the starting current is increased. When pushing to the left, the starting
current is reduced. The starting current is adjusted so that the manual control valve lever starts
activation (flow from the port) when the remote control lever in case of activation has just
passed the dead band. The starting current is adjusted for the other crane functions in the
same way.
12. Push the
ON
button once; the LED display shows ”
Po
” - ”
03
”. The maximum current (final
current) is adjusted here.
13. Activate the remote control lever for a crane function completely. The current is adjusted by
means of the
Micro
tumbler switch, so that the manual control valve lever is just completely
activated when the remote control lever in case of activation is completely activated. The
maximum current is adjusted for the other crane functions in the same way.