GR4000 Installation Guide Version 1.00 - Preliminary
520-10-014-20X
17
Table 1.1-4
LED Indications on the GR4000 - 160E2 Chassis
Name Color
Role
Action
Status
FAN0
Shows the action status of FAN0.
FAN1
Green/Red
Shows the action status of FAN1.
Green (ON): running in normal condition
Red (ON): failure detected
BCU0
Shows the action status of BCU0.
BCU1
Green/
Yellow/
Red
Shows the action status of BCU1.
Green (ON):
operation possible
Yellow (ON): locked out
Green (blinking): in preparation for startup
Red (ON): failure detected
OFF: BCU powered off
(
BCU exchangeable
)
PRU0
(
NIF1/0
)
Shows the action status of PRU0.
PRU1 (NIF3/2
)
Shows the action status of PRU1.
PRU2 (NIF5/4
)
Shows the action status of PRU2.
PRU3 (NIF7/6
)
Green/
Yellow/
Red
Shows the action status of PRU3.
Green (ON):
operation possible
Yellow (ON): locked out
Green (blinking): in preparation for startup
Red (ON): failure detected
OFF: BCU powered off
(
BCU exchangeable
)
(4) Accessories
No accessories provided.
*
NOTE: The rack mounting brackets of GR4000-160E2 are attached to its body
beforehand at the time of shipment.
*
NOTE: Do not install the optional components of GR4000 (or GS4000) into the devices
other than the GR4000 (or GS4000). Doing such a thing causes a fire or an
electric shock.
Содержание GR4000 Series
Страница 1: ...Hitachi Gigabit Router GR4000 Series Installation Guide Version 1 00 Preliminary ...
Страница 98: ...GR4000 Installation Guide Version 1 00 Preliminary 80 520 10 014 20X This page left intentionally blank ...
Страница 152: ...GR4000 Installation Guide Version 1 00 Preliminary 134 520 10 014 20X ...
Страница 164: ...GR4000 Installation Guide Version 1 00 Preliminary 146 520 10 014 20X This page left intentionally blank ...