2.2
Setting Conditions for the GR4000 Models
Table 2.2-1 below outlines the basic conditions required to install the GR4000 models.
Users should place the devices in the environment where all of the following conditions
are satisfied.
When installing the device into a rack, the temperature inside the rack should be within
the range specified for the item “Temperature while running” in Table 2.2-1 below.
Table 2.2-1
Setting conditions for GR4000 models
Specifications
Item
GR4000-
80E1
GR4000
-
160E1
GR4000
-
320E
(AC)
GR4000
-
80E2
GR4000
-
160E2
GR4000
-
320E
(DC)
Dimensions (W x
D x H)
440×490×
230 (mm)
440×490×
441 (mm)
440×674×
578 (mm)
440×674×
147 (mm)
440×674×
289 (mm)
440×674×
578 (mm)
Weight
45 (kg)
80 (kg)
130 (kg)
40 (kg)
70 (kg)
120 (kg)
Input voltage
Single phase
AC100V
(
100V
~
120V
)
Single phase
AC200V
(200V
~
240V)
DC
-
48V
(-
40.5V
~-
57V
)
DC
-
60V
(-
50V
~-
75V
)
Frequency
50
/
60
(
±1Hz
)
-
Input power
required
1000(VA) 1800(VA) 4000(VA) 1000(VA)
2000(VA) 3800(VA)
Quantity of heat
generated (max)
900(W) 1700(W) 3800(W) 1000(W) 2000(W) 3800(W)
Noise
(
Note 1
)
55 db or less 60 dB or less
65 dB or less
55 dB or
less
60 dB or less
65 dB or less
Vibration
2.45m
/
s
2
or less
Dust
(
Note 2
)
5
%/
W or less
(
Note 2
)
or 0.15mg/m
3
or less
(
Note 3
)
Temperature
while running
0
~
40
℃(
23
~
28
℃)(
Note 4
)
Temperature
while not running
-
10
~
43
℃
Temperature
while shipping or
in storage
-
25
~
60
℃
Humidity while
running
10
~
85
%(
45
~
55
%)(
Note 4
)
Humidity while
not running
8
~
85
%
Humidity while
shipping or in
storage
5
~
85
%(
no condensation
)
(Note 1) This should be checked 1 m away from the side panel of the unit.
(Note 2) Based on the measurement of falling dust.
(
See the section 2.7 Environmental Conditions.
)
(Note 3) Based on the Japanese standard to measure the density of floating dust
(
JIS Z 8813
)
.
(Note 4) The figure in “( )” is a recommended value.
Содержание GR4000 Series
Страница 1: ...Hitachi Gigabit Router GR4000 Series Installation Guide Version 1 00 Preliminary ...
Страница 98: ...GR4000 Installation Guide Version 1 00 Preliminary 80 520 10 014 20X This page left intentionally blank ...
Страница 152: ...GR4000 Installation Guide Version 1 00 Preliminary 134 520 10 014 20X ...
Страница 164: ...GR4000 Installation Guide Version 1 00 Preliminary 146 520 10 014 20X This page left intentionally blank ...