61
────────────────────────────────────────────────────
7.4 Commands Specific to the 3157
────────────────────────────────────────────────────
:SYSTem:OPTion:PFHold
■
Sets the PASS/FAIL hold function.
:SYSTem:OPTion:PFHold?
■
Queries the PASS/FAIL hold function.
Syntax
:SYSTem:OPTion:PFHold
_<data>
<data>
Numerical data in NR1 format between 0 and 3
Function
Sets the PASS/FAIL hold function.
0: PASS not held, FAIL held
1: PASS held, FAIL held
2: PASS not held, FAIL not held
3: PASS held, FAIL not held
The numerical value can be in NRf format, but any digits after the decimal
point will be rounded.
Example
Transmission
:SYSTem:OPTion:PFHold 3
The PASS/FAIL hold function is set to "PASS held, FAIL not held."
Error
If <data> is other than numerical value described above, an execution error
occurs.
The execution of this command in a state other than the following states
causes an execution error:
・
READY state
・
Optional function setting screen
Syntax
:SYSTem:OPTion:PFHold?
Function
Returns the PASS/FAIL hold function setting as a numerical value in NR1
format.
<data>
Numerical data in NR1 format between 0 and 3
Example
Response
If headers are on
:SYSTEM:OPTION:PFHOLD 3
If headers are off
3
Error
If the response message is longer than 300 bytes, a query error is generated.
Содержание 9593-02
Страница 2: ......
Страница 6: ...ii Introduction...
Страница 16: ...10 2 3 Specifications...
Страница 76: ...70 8 1 Sample program Flowchart...
Страница 86: ...80 8 2 Sample programs...
Страница 88: ...82...
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......