You can set the exit button as remaining closed or remaining open. Usually, it is remaining
open.
Door Locked Time
After swiping the normal card and relay action, the timer for locking the door starts working.
Extended Open Duration
The door contact can be enabled with appropriate delay after person with extended accesss
needs swipes her/his card.
Door Left Open Timeout Alarm
The alarm can be triggered if the door has not been closed in a configured time period. If it is
set as 0, no alarm will be triggered.
Lock Door when Door Closed
The door can be locked once it is closed even if the Door Locked Time is not reached.
Duress Code
The door can open by inputting the duress code when there is duress. At the same time, the
client can report the duress event.
Super Password
The specific person can open the door by inputting the super password.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer of the card reader (by entering
the dismiss code on the keypad).
Note
• The duress code, super code, and dismiss code should be different.
• The duress code, super password, and the dismiss code should be different from the
authentication password.
• The length of duress code, super password, and the dismiss code is according the device,
usually it should contains 4 to 8 digits.
5. Click OK.
6. Optional: Click Copy to , and then select the door/floor(s) to copy the parameters in the page to
the selected doors/floor(s).
Note
The door or floor's status duration settings will be copied to the selected door/floor(s) as well.
Configure Parameters for Card Reader
After adding the access control device, you can configure its card reader parameters.
DS-K5604A-3XF Series Face Recognition Terminal User Manual
107