Figure 8-18 Black Body Settings
2. Enable black body correction function.
3. Put a black body in front of the camera. Make sure there are no other objects between the
camera and the black body.
4. Set the distance between the black body and the camera (straight line), the emissivity of the
black body, and the temperature unit.
Note
The black body's temperature is fixed.
5. Click Calibrate, and draw the black body's position on the page. When + is displayed on the
black body on the screen, the black body is calibrated.
6. Click Save.
DS-K5604A-3XF Series Face Recognition Terminal User Manual