Calibration
Pipe trolley adjustment
The centre of the pipe trolley must be aligned with the centreline of the machine. There should be no
more than 0.5 mm play between the pipe trolleys wheels and the rails.
●
Place a bar or pipe on the pipe trolley which you know is absolutely straight. For accurate
measurements it should be at least 1 metre long.
●
Measure the distance between the bar (or pipe) and the rails at the 4 points as shown in the diagram.
●
Adjust the wheels until the bar is in the centre to within 1 mm (the 4 measurements should have the
same value).
●
Repeat the procedure for all of the pipe trolleys.