Batch
Enables you to set the batch option to
LoAd
or
u.LoAd
. In this configuration, the parameter MUST
be set for
u.LoAd
for the hen unload batching auger.
Segmented display:
22. Press the SELECT key to enter BATCH menu, and
.
should be displayed (If
is displayed,
press
to set to
.
).
23. Press the SELECT key and then
is shown.
24. Press
and
. .
is displayed.
Capacity (L.C.Cap)
The load cell system capacity is the sum of all the load cells rated capacity in either pounds or kilograms. This
parameter sets the calibration of the system. To determine this value, multiply the number of load cells by their
capacity.
Example: A four leg bin with 5k load cells would require an L.C.CAP setting of 20000 pounds.
Segmented display:
25. Press the SELECT key.
26. The REMOTE display will mirror the value you entered on the MASTER display. Verify that this is the case
and that the L.C.CAP matches what you entered on the MASTER display. Now, press the SELECT key.
End
Allows the user to exit SETUP mode.
27. Press the
key 5 times until
is displayed. Press the SELECT key to exit SETUP mode.