Operation Manual
Version 2.0
20
Part Number MAN-000009
Setup Parameters
Follow the system wiring diagram (
) to aid in the installation process, including supplied relays and switches.
Once installation is completed, the BinTrac Breeder Control unit must be programmed as summarized below:
1. The BinTrac Breeder Control console controls the unload batching withdrawal auger (
steps 1 through 19
).
Access SETUP mode and configure the following:
•
Set the Batch type to Unload Batching
•
Set an
L.C.CAP
value that matches the total capacity of all load cells
•
Set a
FuLL
value that matches the maximum capacity of the weigh bin
•
Set the
Hour
time parameter (default is CST Zone)
System Settings in Setup Mode
The SETUP mode is used to configure the one-time system setup settings for the appropriate
configuration. The following SETUP parameters MUST be correctly configured to ensure proper
operation and weighing:
•
BATCH
•
L.C.CAP
•
FULL
•
ZERO
•
HOUR
NOTE
: When first powering on the unit
.
will be displayed, simply as a reminder that the
load cell capacity for the system must be entered in the SETUP menu to ensure proper weighing
calibration.
NOTE
: If there is no activity for a period of time while in SETUP mode, the system will exit and
return to the Weight Display mode.
Navigating Setup Mode
To navigate through the options in Setup mode, use the
and
keys to cycle through the
options/parameters. See the SETUP menu flow chart to the right.
Accessing the Setup Mode
1. Press and hold the SELECT button down until
is displayed.
Segmented display:
2. Press the
and
will be displayed.
SETUP Menu
Flow Chart
Содержание BinTrac Breeder Control
Страница 18: ...Operation Manual Version 2 0 18 Part Number MAN 000009 Wiring Diagram...
Страница 25: ...Operation Manual Version 2 0 25 Part Number MAN 000009 Wiring Diagram OPTIONAL...
Страница 36: ...Operation Manual Version 2 0 36 Part Number MAN 000009 Wiring Diagram...