Operation Manual
Version 2.0
14
Part Number MAN-000009
Batch
Enables you to set the batch option to
LoAd
or
u.LoAd
. In this configuration, the parameter MUST be set for
LoAd
to batch from the inventory bin into the weigh bin.
Segmented display:
3. Press the SELECT key to enter BATCH menu, and
.
should be displayed.
Press
to set to
.
4. Press the SELECT key and then
is shown.
5. Press
and
. .
is displayed.
Capacity (L.C.CAP)
The load cell system capacity is the sum of all the load cells rated capacity in either pounds or kilograms. This
parameter sets the calibration of the system. To determine this value, multiply the number of load cells by their
capacity.
Example: A four leg bin with 5k load cells would require an L.C.CAP setting of 20000 pounds.
Segmented display:
6. Press the SELECT key. The display will show the current setting (default is 30000).
7. Use the
and
keys to increase or decrease the value. Hold the key down to increase/decrease quickly.
8. Upon setting the appropriate value, press SELECT and the display will show
.
9. Press the
key and
is displayed.
Full Value
This value is the maximum weight of a full bin in either pounds or kilograms as is for calibration of the LED bar graph
level. The value determines at what weight the bar graph will display completely full (all 16 LEDs lit). Set this to the
maximum amount of feed that you would consider the bin to be full.
Segmented display:
10. Press the SELECT key.
11. Use the
and
keys to increase or decrease the value. Hold the key down to increase/decrease quickly.
12. Upon setting the appropriate value, press SELECT and the display will show
.
Содержание BinTrac Breeder Control
Страница 18: ...Operation Manual Version 2 0 18 Part Number MAN 000009 Wiring Diagram...
Страница 25: ...Operation Manual Version 2 0 25 Part Number MAN 000009 Wiring Diagram OPTIONAL...
Страница 36: ...Operation Manual Version 2 0 36 Part Number MAN 000009 Wiring Diagram...
Страница 47: ...Operation Manual Version 2 0 47 Part Number MAN 000009 Wiring Diagram...