Operation Manual
Version 2.0
42
Part Number MAN-000009
System Settings in Setup Mode - REMOTE
The SETUP mode is used to configure the one-time system setup settings for the appropriate configuration. The
following SETUP parameters MUST be correctly configured on the REMOTE Breeder console to ensure proper
operation and weighing:
•
SETUP
•
BATCH
•
L.C.CAP
NOTE
: When first powering on the unit,
.
will be displayed. This is simply a reminder that the load cell
capacity for the system must be entered in the SETUP menu to ensure proper weighing calibration.
NOTE
: If there is no activity for a period of time while in SETUP mode, the system will exit and return to the Weight
Display mode.
Navigating Setup Mode
To navigate through the options in SETUP mode, use the
and
keys to cycle through the
options/parameters. See the SETUP menu flow chart to the right.
Accessing the Setup Mode
20. Press and hold the SELECT button down until
is displayed.
Segmented display:
Enabling Peripherals in Setup Mode
In the SETUP Mode, the four LEDs indicate configuration options as being enabled
(solid on) or disabled (flashing). For this configuration, only the GROSS WEIGHT LED
should be solid on, enabling the unit as a Remote Display.
Note: If the MASTER Indicator has already been set to enable peripherals and is connected to
the REMOTE display, the GROSS WEIGHT LED should already be solid on in the SETUP menu.
If this is the case, simply press the
key once to move to
and then skip step 21.
21. Press the SELECT key one time and then use the
key to enable Remote Display in the
SETUP mode (GROSS WEIGHT LED should be on solid on). Press the SELECT key four
times and
will be displayed.
GROSS WEIGHT
-Configures a BinTrac or Breeder Indicator as a Remote Display
automatically when connected to a Master Breeder Control with
Peripheral Devices enabled.
BATCH AMT
-NOT USED
LED (left of RUN)
-NOT USED.
RUN
-Enable communications to Peripheral devices. Must be enabled
when Breeder Control is connected to a Remote Display device
(REMOTE BinTrac Indicator or Breeder Control console).
SETUP Menu
Flow Chart
Содержание BinTrac Breeder Control
Страница 18: ...Operation Manual Version 2 0 18 Part Number MAN 000009 Wiring Diagram...
Страница 25: ...Operation Manual Version 2 0 25 Part Number MAN 000009 Wiring Diagram OPTIONAL...
Страница 36: ...Operation Manual Version 2 0 36 Part Number MAN 000009 Wiring Diagram...