Operation Manual
Version 2.0
8
Part Number MAN-000009
Batch
Enables you to set the batch option to
LoAd
or
u.LoAd
(unload).
LoAd
is used when you want material batched into
a bin. Based on the gross weight of the bin, material is batched into the bin until the batched amount equals the gross
amount.
u.LoAd
is used when you want material batched out of a bin. In this case, the bin is holding a bulk amount of
feed and will batch out the programmed batch amount.
1. Press the SELECT key to enter menu.
2. Use the
or
keys to select
or
.
.
Segmented display:
Rated Value
The average rated output in millivolt/volt (mV/V) of the load cells. If using load cells
other
than the HerdStar load
cells, you may need adjust this value appropriately.
*
IMPORTANT
–
DO NOT change this setting from the default of 3.000 if you are using HerdStar load cells
.
1. Press the BIN key to select the desired bin.
2. Use the UPPER
key to increase the rated output by 0.001.
3. Use the LOWER
key to decrease the rated output by 0.001.
Segmented display:
Load Cell Capacity Value
Sets the total capacity of each bin. The total capacity is the sum of all the load cells rated capacity. This can be
calculated by multiplying the capacity of individual load cells by the number of legs on the bin. Example: A four-
legged bin using 10k load cells would result in an L.C.CAP setting of 40000.
Note:
When setting up for kilograms, convert the total capacity to kilograms.
1. Press the BIN key to select the desired bin.
2. Use the UPPER
key to increase the value by 1 lb.
3. Use the LOWER
key to decrease the value by 1 lb.
Segmented Display:
Содержание BinTrac Breeder Control
Страница 18: ...Operation Manual Version 2 0 18 Part Number MAN 000009 Wiring Diagram...
Страница 25: ...Operation Manual Version 2 0 25 Part Number MAN 000009 Wiring Diagram OPTIONAL...
Страница 36: ...Operation Manual Version 2 0 36 Part Number MAN 000009 Wiring Diagram...
Страница 47: ...Operation Manual Version 2 0 47 Part Number MAN 000009 Wiring Diagram...