19
During normal operation, the control automatically monitors
the oil level in the vat. If the control senses the oil level too
low, the unit automatically pumps oil from the BIB into the vat
to keep the oil at the proper level.
Manual Top-Off
If the oil level is a little low, oil can be added to the vat at any
time from the BIB to raise the oil level to the proper level by
following the steps below. This procedure is NOT to be used
to fill an empty vat
1. Press and hold (either one-full vat) until display
shows “*FILTER MENU*”, along with “1.EXPRESS
FILTER”.
2. Press
5 times until “6.FILL FROM BIB” shows in
the display.
3. Press
ü
button, “FILL VAT” “
ü
=PUMP” “
X
=DONE” is
displayed.
4. Press and hold
ü
button and display shows “FILLING”
and the oil is pumped from the BIB to the vat.
5. Once vat is full, release
ü
button, “FILL VAT”
“
ü
=PUMP” “
X
=DONE” displays. Press
X
button twice
for normal operation
When selecting a product, if “XXX XXX” shows in the dis-
play, the setpoint temperature is not correct for this product.
To change the setpoint temperature for the desired product:
1.
Press product button, for ex: (FRY).
2.
Display shows “XXX XXX”.
3.
Press and hold a timer button or for 5
seconds and then “FRY” shows in display.
4.
Allow oil temperature to reach setpoint temperature
before dropping product.
1. Control displays “BIB IS LOW” and an alarm sounds.
2. Open right door and pull BIB from unit. Pull the cap from
top of BIB and discard empty BIB and replace with full
one. Figure 1
3-8. SELECTING A PRODUCT
WITH A DIFFERENT
SETPOINT
3-9
.
a
REPLACING THE BIB
Figure 1
3-7. OIL GUARDIAN™
(Auto Top-Off)
Aug. 2011