69
6-3. CLOCK SET
1. Press and hold the button for 5 seconds until “LEVEL
2”, followed by, “SP PROG” and “ENTER CODE” show in
the display.
2. Press the button again and “CLK SET” and “ENTER
CODE” flash in the left display.
3. Enter code 1, 2, 3 (first 3 product buttons).
4. “CS-1 ENTER DATE MM-DD-YY” flashes in the left
display. Use the product buttons to set the date in the right
display.
5. Press button and “CS-2 ENTER TIME” flashes in the
left display and the time flashes in the right display. Press
the or , or use product buttons, to change the time.
6. Press button and “CS-2 ENTER TIME” flashes in the
left display and “AM” or “PM” flashes in the right display.
Use the or buttons to choose AM or PM.
7. Press button and “CS-3 TIME FORMAT” flashes in
the left display and “12-HR” or “24-HR” shows in the right
display. Use the or buttons to choose a 12 hour
time format or a 24 hour time format.
8. Press button and “CS-4 DAYLIGHT SAVING TIME”
flashes in the left display. Use the or buttons to
choose daylight saving time for your area: 1.OFF; 2.US
(2007 & after); 3.EURO; or 4.FSA (US before 2007).
The Data Logging, Heat Control, Tech, Stat and Filter Control
Modes are advanced diagnostic and program modes, mainly for
Henny Penny use only. For more information on these modes,
contact the Service Department at 1-800-417- 8405 or 1-937-
456-8405.
6-4. DATA LOGGING, HEAT
CONTROL, TECH, STAT,
AND FILTER CONTROL
MODES
Aug. 2011