66
6-1. SPECIAL PROGRAM
MODE (Continued)
Autolift Enabled (SP-21)
Press
button and “SP-21 AUTOLIFT ENABLED?”
flashes in the left display. Press the or buttons
to choose “YES LIFT” or “NO LIFT”.
If fryer is fitted with the auto-lift option, SP-21 must be set
to “YES LIFT”, otherwise, set SP-21 to “NO LIFT”.
Bulk Oil Supply (SP-22)
Press
button and “SP-22 BULK OIL SUPPLY?”
flashes in the left display. Press the or buttons
to choose “YES SUPL” or “NO SUPL”.
Set to YES if the oil is pumped into the vats from an
outside oil reservoir. Otherwise, set SP-22 to NO.
Bulk Oil Disposal (SP-23)
Press
button and “SP-23 BULK OIL DISPOSE?”
flashes in the left display. Press the or buttons
to choose “YES DISP” or “NO DISP”.
Set to “YES DISP” if the oil is pumped from the vats to an
outside oil reservoir when disarding the oil. Otherwise, set
SP-23 to “NO DISP”.
Serial Number Log (SP-24)
Press
button and “SP-24 S/N
ü
EDIT” flashes in the
displays, along with the serial number of the unit. THIS
SERIAL NUMBER SHOULD MATCH THE SERIAL
NUMBER ON THE DATA PLATE, ON THE DOORS. IF
NOT, IT CAN BE RECORDED.
Program Code Change (SP-25)
This allows the operator to change the program code (factory
set at 1, 2, 3) used to access Product Programming and Level 2
Program Mode.
Press
button and “SP-25 CHANGE MGR CODE?
1=YES” flash in the display. Press
and “ENTER
NEW CODE, P=DONE, I=QUIT show scrolls through the
display. Press the product buttons for new code.
If satisfied with code, press and “REPEAT NEW
CODE, P=DONE, I=QUIT, shows in display. Press same
code buttons.
Aug. 2011