46
3-19. INFO BUTTON STATS
Actual Oil Temperature
1. Press and the actual oil temperature shows in the
display, for each vat.
Set-point Temperature
2. Press twice and SP shows in the display, along with
the set-point (preset) temperature of each vat.
Recovery Information for each Vat
3. Press 3 times and REC shows in the left display and
the recovery time that oil temperature went from 250°F
(121°C) to 300°F (149°C) shows in the right display.
For example, “REC 5:30” means it took 5 minutes and 30
seconds for the oil temperature to recover to 300°F (149°C)
from 250°F (121°C).
If no buttons are pressed within 5 seconds in any of stats
modes, the controls revert back to normal operation.
Cook Cycles Remaining before Filtering
1. Press and release either button and the left display
shows “COOKS REMAINING” and the right display
shows the number of cook cycles before the next auto filter.
For example, “REMAINING” “3” “6” means after 3 more
cook cycles on the left vat, the controls asks the operator if
they are ready to filter or not. But, 6 more cook cycles
remain on the right vat.
Time and Date
2. Press either twice and ‘FILTERED” shows in the
diplays, along with the time-of-day and date of the last
filter.
3-20. FILTER BUTTON STATS
Aug. 2011