![HBK DSE Скачать руководство пользователя страница 189](http://html1.mh-extra.com/html/hbk/dse/dse_operating-manual_2111691189.webp)
DSE
INDUSTRIAL ETHERNET
88
Kommentar
Erklärung
R/W
Datentyp
Subindex
[hex]
Index [hex]
2240
5
U16
WO Filler commands
Bit 0: Start dosieren
Bit 1: Stopp dosieren
Bit 2: Löschen Dosierergebnis
2D00 2
U16
RO
Filler process status
IDLE: 0
START_DELAY: 1
START_WEIGHT: 2
TARE: 3
FIRST_FINE_LOCKOUT: 4
FIRST_FINE_FLOW: 5
COARSE_FLOW_LOCKOUT: 6
COARSE_FLOW: 7
FINE_FLOW_LOCKOUT: 8
FINE_FLOW: 9
RESIDUAL_FLOW: 10
TOLERANCE_CONTROL: 11
REFILLING: 12
READY: 13
EMPTYING: 14
2D00 3
U16
RO
Filler valve status
Bit 0: Ventilsteuerung grob
Bit 1: Ventilsteuerung fein