HB-100/140/160Z1
Temperature Control Unit
Structure and function
O8285-EN 2017-12
31
4.6 Additional equipment
The following additional equipment can be installed in addition to
the basic equipment for the unit (
nameplate):
Additional equipment
Description
ZL
Leak stopper
With automatic depression optimisation (up to 70 °C)
ZG
Mould evacuation with compressed air Alternative to the standard integrated Mould evacuation by
pump inversion
ZB
Connection for alarm and external
control
Alarm via a potential-free changeover contact
rating max. 250 V AC, 4 A
Device ON/OFF, ramp program ON/OFF and switching
nominal value 1 or 2 via potential-free contact
1 plug connector Harting Han 7D
ZE
Connection for external sensor
Thermocouple type J, K, T or Pt 100 in 3-wire
System, with selectable production detector
1 socket audio 5-pin
ZD
Interface DIGITAL
Serial data interface 20 mA, RS-232 or RS-422/485
Various protocols selectable: Arburg, Billion, Bühler, Dr. Boy,
Engel, Ferromatik Milacron, Haitian, KraussMaffei, MODBUS
(RTU-Mode), Negri Bossi, SPI, Stork, Sumitomo Demag,
Wittmann Battenfeld, Zhafir
2 sockets sub-D 25 pin
ZC
Interface CAN
Series data interface CAN-Bus (Sumitomo Demag) and
CANopen (EUROMAP 66)
To remotely control singular units
1 socket / 1 plug sub-D 9 pin
ZO
OPC UA interface
Ethernet interface
1 socket RJ-45
ZP
Interface PROFIBUS-DP
Serial data interface PROFIBUS-DP
1 socket sub-D 9 pin (not possible with ZC)
ZU
Pump status monitoring
Additional pressure sensor in main line
ZK
Keyboard-protection
Transparent flap over display and controls
ZR
Clean room package
Clean room compatible version
“At Rest” < ISO Class 6 (Kl. 1000)
“In Operation” ISO Class 7 (Kl. 10 000)
Fibre-free insulation
X
Special Design
Special design without additional description
XA
Special Design with appendix
Special design with additional description in Appendix A