HB-100/140/160Z1
Temperature Control Unit
Operation
70
O8285-EN 2017-12
Production detection
Fig. 37: Level production detector
For applications with the sensor close to the cavity, physically
caused temperature deviations due to production interruptions can
occur. When production detection is switched on, switchover is
made to main line control on production interruption. Temperature
deviations are avoided.
Proceed as follows in order to switch production detection on and
off:
1.
Display the menu page
Setting \ Controller
.
2.
Set parameter
Level production detector
to "15 K".
NOTE!
The default setting is "OFF".
Sensor breakage external sensor
On breakage of the external sensor, with the setting
Switch over
exernal sensor
"autom", automatic switching is made to the internal
measuring point; with the setting "manual", an error message
results.