8.7 Emergency stop
In dangerous situations, the unit must be stopped as quickly as
possible and the power supply switched off.
Emergency stop
Fig. 49: Main switch
Proceed as follows in a hazardous situation:
1.
Turn the main switch to "0".
2.
Disconnect from the mains or disconnect all phases of the
external power supply and secure them against being
switched on again.
3.
If necessary, bring people out of the danger area and carry
out first-aid.
4.
If necessary, alert a doctor and the fire brigade.
5.
Inform the responsible person on site.
After rescue measures
6.
If required by the severity of the emergency, inform the
responsible authorities.
7.
Commission qualified personnel to do the fault rectification.
WARNING!
Danger of life due to premature re-activation!
On restarting there is a danger of fatal injury for
people in the danger area.
Therefore:
Before restarting, ensure that there are no persons
in the danger area.
8.
Before recommissioning, check the unit for perfect functioning.