HB-100/140/160Z1
Temperature Control Unit
Control
58
O8285-EN 2017-12
Tool 1-10
E
-
-
-
-
-
Tool no.
E
4
--
-
-
M
Nominal value 1
E
4
--
°C
-
M
Difference return/main line
E
4
--
K
-
M
Difference main line/external
E
4
--
K
-
M
Upper dev. nominal/actual
E
4
--
K
-
M
Lower dev. nominal/actual
E
4
--
K
-
M
Flow rate internal max.
E
4
--
L/min
-
M
Flow rate internal min.
E
4
--
L/min
-
M
Load tool data
E
4
OFF
-
-
M
Save tool data
E
4
OFF
-
-
M
export tool data
E
4
OFF
-
-
M
import tool data
E
4
OFF
-
-
M
lo
Level
U
-
-
-
-
-
Level premonition
U
4
5
%
200/250T
M
lo
Setting
S
-
-
-
-
-
lo
Remote
S
-
-
-
-
-
Address
S
3
1
-
-
M
Protocol
S
3
1
-
-
A
Master external control
E
3
autonom.
-
-
A
Transfer rate
E
4
4800
B/s
-
A
Transfer rate CAN Bus
E
4
250
k/s
-
A
Decimal place flow rate CAN
S
4
ON
-
-
A
Parity
E
4
even
-
-
A
Data bit
E
4
8
-
-
A
Stop bit
E
4
1
-
-
A
Serial recording cycle
S
4
1
s
-
A
Delay emergency switch off
U
4
30
s
-
M
Compatibility Profibus to S4
S
4
yes
-
-
A
Profibus node 1
S
4
5
-
-
A
Profibus node 2
S
4
6
-
-
A
Profibus node 3
S
4
7
-
-
A
Profibus node 4
S
4
8
-
-
A
Simulate DFM as device
E
3
OFF
-
-
M
Operate unit as a module
S
3
OFF
-
-
A
TCP/IP Configuration
S
-
-
-
ZO
-
DHCP
U
4
yes
-
ZO
A
DHCP addressing successful
U
4
-
-
ZO
A
IP
U
4
-
-
ZO
A
Subnet mask
U
4
-
-
ZO
A
Standard gateway
U
4
-
-
ZO
A
Port
U
4
4840
-
ZO
A
Mac Address
U
4
-
-
ZO
A
Em. Shutdown Ses. Timeout
U
4
no
-
ZO
A