Exterior Projection 1000 User Manual
9
6. See illustration on right. Avoid dropping
cable ties or other items into the fixture.
Using scissors or cutting pliers, cut and
remove the two cable ties (arrowed).
7. See illustration on right. If you unclipped the top
cover safety cable, reattach it so that it will catch
the top cover and prevent it from falling.
•
If the fixture will not be opened again before it
is used, follow the correct procedure for
reducing humidity when closing it: follow the
instructions in ‘Removing and reinstalling the
top cover’ on page 36.
•
If the fixture will be opened again before it is
used, there is no need to follow the procedure
for reducing humidity and you can simply go to
the next step below.
8. Put the top cover back into position on the fixture and reinstall the eight top cover screws by
first inserting them finger-tight. Then use a torque driver and cross-tighten the screws in a
diagonal pattern, increasing torque gradually in stages until you reach a torque of 1.9 – 3.5
Nm.
9. See illustration on right. Remove the cover (arrowed)
from the control panel and display on the side of the
fixture so that you can set up the fixture using the control
panel.
10. If the temperature is below -20° C (-4° F), apply power to
the fixture but do not use it for 30 minutes. This will give
the fixture time to warm up to within its operating
temperature range.
Whenever AC power is applied to the fixture, it will reset all
effects and functions to their home positions. Reset is
available when fixture temperature is above -20° C (-4° F).
After the reset, the fixture will be ready for DMX control or
standalone operation.