16
Exterior Projection 1000 User Manual
AC power
Read ’Safety information’ on page 5 before connecting the fixture to AC mains power.
Lock out power to the entire installation before working on cables and connections.
Electrical installation must be carried out by qualified professionals only.
For protection from dangerous electric shock, the fixture must be grounded (earthed). The
AC power distribution system must be fitted with current overload and ground-fault (earth-
fault) circuit breakers as well as a means to isolate fixtures from power and lock out power
during service.
The Exterior Projection 1000 is supplied in EU and US models. Both models accept AC power at
100-240 V nominal or 277 V
nominal at 50 or 60 Hz. Do not connect to power at any other voltage
or frequency.
You can connect the Exterior Projection 1000 to either of the following mains power distribution
systems:
•
Single-phase (live, neutral, ground/earth) system.
•
Grounded/earthed three-phase four-wire (three phases, neutral, ground/earth) system.
Do not try to connect to a three-phase three-wire (three phases, ground/earth) system.
There is no power on/off switch. Power is applied to an Exterior Projection 1000 fixture as soon as
it is connected to power. Provide a means to disconnect or shut down power to fixtures that is
easily accessible and is located close to the fixtures.
Do not use an external dimming system to supply power to the fixture, as this may cause damage
to the fixture that is not covered by the product warranty.
Protecting connections from moisture
Moisture can cause corrosion in unprotected cable connections. Moisture can also be sucked
along the inside of cables at breaks or cuts in the cable jacket (for example at connection points)
and into fixtures because of the vacuum effect of temperature fluctuations inside fixtures. To
protect connections and fixtures from moisture, take at least one of the following precautions:
● Locate cable junctions in dry areas (e.g. junction boxes in dry locations).
● Use connectors or junction boxes that are protected to IP67 or higher.
● Fill junction boxes with potting compound to seal the ends of cables and to protect connections
from corrosion.
Connecting to AC mains power
The fixture is supplied with a power cable installed ready for connection. See illustration below:
AC power cable
To connect to a single-phase system or to one phase of a three-phase four-wire system:
1. Lock out power to the installation.
Содержание Martin Exterior Projection 1000