114
XIV. Operation and notice about LPG forklift
1.5-3.5t LPG Forklift for more details refer to
《
R & XF Series 1.0t-3.5t LPG Forklift
Operation and maintenance manual)
》
.
4.0t-x5.5t
Equipped with American GM4.3 LX Dual fuel engine
CPYD40-XW57
、
CPYD45-XW57
、
CPYD50-XXW57
、
CPYD55-XXW57
CPQYD40-XW57
、
CPQYD45-XW57
、
CPQYD50-XXW57
、
CPQYD55-XXW57
LPG fuel system consists of cylinder, filter, press reducing regulator, mixer, etc.. LPG is from
cylinder to combination valve and high pressure pipeline, then pass filter and last into reducer. After
boiloff into mixer, commix with air boiloff in fixed proportion, burnt in engine cylinder, drive forklift to
work. GM 4.3L engine equip with press reducing regulator and mixer.
1. LPG fueling and replace
After the fuel in cylinder is run out, replace it. First close the outlet
stop
valve, disconnect quick
coupling, put the quick connectors on the cylinder outlet valve with dust cover, remove the
cylinder and fuel it at gas station. During fueling, lay down the cylinder, put the inlet meter valve
on top(liquid level indicating meter to horizontal line at 60°degree angle at this time), and then
screw off the dust cover on the inflation valve, insert inflation plug, open the inlet limit valve to
fuel. When the LPG fuel to 80% of the cylinder volume, take out the inflation plug( when fuel to
80% of rated volume, its limit device will shut down automatically). After finishing fueling, take
out the plug, screw on the dust cover of inflation valve, and tighten the inlet limit valve.
After install the cylinder in certain angle(liquid level indicating meter to horizontal line at
60°degree angle), connect pipeline with quick connector, turn on the outlet
stop
valve switch to
check if there is air leakage, otherwise eliminate it. Then start the truck. Close it after truck use.
11
3
2
1
4
6
7
8
5
9
10
Schematic diagram of cylinder end face
1. Inflation valve
2. Dust cover
3. Inlet input port
4. Inlet Limit Valve
5. UP installion label 6. Safety valve
7. Level indicator
8. Outlet Stop Valve
9. vent connector
10. Female adapter
11. Dustproof cap
2.
The operation of dual fuel switch
1.
Turn switch to GAS, then fuel is switched to
gasoline;
2.
Turn switch to LPG, then fuel is switched to LPG;
3. Middle position, no connection.
3.
Starting the engine
(
1
)
By gasoline
Shut off LPG tank, switch on the gasoline switch for several seconds, turn the ignition key to start
the motor-----the engine starts;