(10) The LPG conform to GB11174 can be recharging; the maximum volume is no more than 80%
of cylinder.
(11) The LPG must be charging at the place awarded by qualified Quality and Technical
Supervision Bureau, do not fill by self.
(12)
Charging unit must vacuumize or displace with nitrogen when the new or recheck cylinder is
used at the first time.
(13)
Before reinstalling cylinder, lay the cylinder horizontal perpendicular to installing sign, close
outlet shutoff valve, open inlet shutoff valve, see the finger of fluid indicator whether is lifting
with the charging fluid when charging. Stop charging when the limit charging valve is working
in time, and check whether the finger of fluid indicator is at the correct position. Close inlet
shutoff valve after charging out.
(14)
Check the forklift truck fully ahead to ensure no leak of LPG, then open the LPG outpouring
valve on the LPG cylinder, check more to ensure no leak of LPG fuel system before
starting-up.
(15)
If there is LPG leak during operation, shut off the LPG switch and the outpouring valve at once,
check every part and all connections to see if there is a leak or it‘s loose, and replace it in time.
Fuel by petrol before malfunction is removed.
(16)
If there is more than a 10 minutes stoppage in operation, you should shut off the LPG switch
and the outpouring valve.
(17)
Avoid leaving cylinder in the sun for prolonged periods, and keep it far away from heat sources,
and forbidden to heat cylinder with heat source which the temperature is more than 40°C.
(18)
It should have no less than 0.5% the cylinder volume to remain.
(19)
It is forbidden to modify cylinder mark and color sign.
(20)
Cylinder must be taken to the special unit per 5 years to inspect, the unit have qualification
awarded by pressure vessel safety supervisor bureau.
(21)
Observe the level indication frequently during operation, if it is found that LPG consumption is
not in proportion to working time, you should stop to check where leaks, and shut off power,
the LPG valve and all valves concerned at once to take good measure in time.
(22)
Park the truck in shady and ventilated sites; close the valves on the LPG cylinder. Never leave
the truck in the sun for a prolonged period.
(23)
Shut off power and all valves after the truck is garaged. Keep well-ventilated and extinguishing
measure in the garage.
(24)
Never repair the LPG cylinder, valves or pipes at garages or parking lots, or in the presence of
anyone smoking.
12. Service & maintenance
1)
This truck has undergone pressure trials and performance testing before leaving factory. If there
is performance failure, strictly forbid repairing without permission.
2)
Close the valves on the LPG cylinder before disassembly and maintenance of the LPG device.
3)
Suitably adjust the measure valve, for LPG consumption varies seasonally.
4)
Often check and clean the air cleaner and the LPG filter, replace it with a new one in time if it is
damaged.
5)
After finishing the LPG forklift debugging and one day well run (or a full container of LPG is used
up), you should adjust the LPG vaporizer again to ensure proper ratio of fuel to air.
6)
Check the electric system every three months if any switch connection-peg is oxidized or rusted,
and replace it in time.
7)
Take routine care for the whole LPG fuel system every year working, that is, clean the vaporizer,
check airproof capacity of each tie-in in the high pressurized pipes and the low pressurized