119
Item
Quality index
Test method
Sulphuretted hydrogen
None
None
None
SH/T 0125
Free water
None
None
None
Eyeballing
Note 1
:
Gaseity content, total sulfur content is at 0
℃
, 101.35kPa.
Note 2
:
It can be measured whether it exists free water by eyeballing when measuring
density.
a Evaporation pressure can be evaluated by GB/T 12576
,
measured by GB/T 6602 when
arbitration.
b Component can be measured by SH/T 0230, but measured by SH/T 0614 when
arbitration.
c Density can be measured by GB/T 12576, but measured by SH/T 0221 when arbitration.
d Total sulfur content can be measured by SY/T 7508
,
but measured by SH/T 0222
when arbitration.
From : PRC STANDARD LPG IN VEHICLE
(
GB 19159-2003
)
9.
Procedure for replacing LPG cylinder
(
1
)
Wear canvas gloves to avoid leaking gas from preventing frostbite to fingers while
changing gas.
(
2
)
Make sure the place is clear and well-ventilated when charging LPG, it is forbidden to
smoke ,keep away from other naked flame.
(
3
)
Fill LPG as follows: Lay the LPG cylinder flat, and set the charging limit valve upward,
then screw off the dust cap on the inlet shut off valve, plug the filling connector, open the
inlet shutoff valve to charge LPG till 80% of rated volume of the cylinder (the charging
device is automatically closed when charge to 80% of rated volume), take out the filling
connector, screw down the dust cap and the inlet shut off valve. Check all parts and make
sure they are all intact.
(
4
)
Lift the cylinder up to truck, and fix it, put the arrow
(
5
)
upward, then insert the fixed pin
to cylinder.
11
3
2
1
4
6
7
8
5
9
10
115
Содержание XF Series
Страница 127: ...123 pipes IMPCO single fuel system 120...
Страница 128: ...124 LPG system drawing...