SmartFOAM
Distribution Box
(Early and Pre 2017)
The Distribution Box (part of the pump/motor assembly) con-
trols the speed of the pump/motor based on commands from
the SmartFOAM controller display. The distribution box also
receives the signal from the foam feedback sensor, low tank
sensor(s), and tank selector and relays that information back
to the SmartFOAM controller display.
Figure 81: Distribution Box LEDs
The distribution box contains six internal LEDs to help with
diagnostics (refer to Figure 70: Distribution Box LEDs).
❑
TNKA
is illuminated when the tank selector is set to
“tank A”. This is based on a physical input into pin 4
of the gray connector on the front of the distribution
box.
(When the TNKA and TNKB LEDs are OFF the
system is in FLUSH mode).
❑
TNKB
is illuminated when the tank selector is set to
“tank B”. This is based on a physical input into pin 5
of the gray connector on the front of the distribution
box.
(When the TNKA and TNKB LEDs are OFF the
system is in FLUSH mode).
❑
VCC
is illuminated when power and ground are ap-
plied to the distribution box pins 1 and 12. This indi-
cates that the internal 5 volt regulator is functioning
for the internal components.
❑
VIGN
is illuminated when power and ground are ap-
plied to the distribution box pins 1 and 12. This indi-
cates that system power and ground are recognized
within the unit.
❑
DPWR
is illuminated when the “IN” power stud is en-
ergized with system voltage. This power is required
to drive the motor attached to the pump.
❑
COM
is illuminated when the distribution box is com-
municating with the SmartFOAM controller display
via the CAN. This LED with be flashing if there is a
CAN communication problem and it cannot com-
municate with the SmartFOAM controller display.
If no tank selector (MST, MDTII, ADT) is used a connector
plug is installed to connector C8 to lock the system in the
Tank A mode (
and
). Removing this plug
or disconnecting the tank selector cable and places the sys-
tem in the FLUSH mode.
Distribution Box
(Late 2017 and Newer)
Figure 82: 610-00044 New Distribution Box
The distribution box was upgraded Fall 2017 to 610-00044.
This new distribution box has improved protection against
overcurrent. There are three inputs (green, black, and grey),
but only the grey is utilized for foam units. The black con-
nector is power. There are three standalone indicator lights
on the top of the case:
❑
SYSTEM PWR
is illuminated when the “IN” power
stud is energized with system voltage. This power is
required to drive the motor attached to the pump.
❑
MOTOR PWR
is illuminated when there is power
output to the foam motor.
❑
COM
is illuminated when the distribution box is com-
municating with the SmartFOAM controller display
via the CAN. This LED with be flashing if there is a
CAN communication problem and it cannot com-
municate with the SmartFOAM controller display.
Содержание MiniCAFS 2.1A
Страница 3: ...Page 2 SmartFOAM NOTES...
Страница 12: ...Page 11 SmartFOAM HALE FOAM PUMP DIMENSIONS Figure 1 1 7 and 2 1 Foam Pump Installation Envelope Dimensions...
Страница 15: ...Page 14 SmartFOAM Figure 5 Converter Installation Envelope Dimensions Located Remote for 6 5 12VDC Systems...
Страница 16: ...Page 15 SmartFOAM SYSTEM DIAGRAM Figure 6 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Страница 17: ...Page 16 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Страница 18: ...Page 17 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Страница 19: ...Page 18 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Страница 20: ...Page 19 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainers...
Страница 21: ...Page 20 SmartFOAM Figure 11 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Страница 22: ...Page 21 SmartFOAM Figure 12 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandIn lineStrainers...
Страница 23: ...Page 22 SmartFOAM Figure 13 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandFSSeries Strainers...
Страница 24: ...Page 23 SmartFOAM Figure 14 SmartFOAM Dual Pump 1 Single Tank with Valve Options and In Line Strainers...
Страница 25: ...Page 24 SmartFOAM Figure 15 SmartFOAM Dual Pump 1 Single Tank System with MST and FS Series Strainers...
Страница 26: ...Page 25 SmartFOAM Figure 16 SmartFOAM Dual Pump 1 Dual Tank System with MDT II and FS Series Strainers...
Страница 27: ...Page 26 SmartFOAM Figure 17 SmartFOAM Dual Pump 2 Single Tank System with valve options and In Line Strainers...
Страница 28: ...Page 27 SmartFOAM Figure 18 SmartFOAM Dual Pump 2 Single Tank System with MST and FS Series Strainers...
Страница 29: ...Page 28 SmartFOAM Figure 19 SmartFOAM Dual Pump 2 Dual Tank System with MDT II and FS Series Strainers...
Страница 48: ...Page 47 SmartFOAM Figure 28 Typical 4 Inch Check Valve Installation Midship Pump...
Страница 59: ...Page 58 SmartFOAM Figure 43 ADT Option Air Hose Connections Part 2...
Страница 68: ...Page 67 SmartFOAM Figure 55 Top Mount Low Level Sensor Assembly...
Страница 77: ...Page 76 SmartFOAM NOTES...
Страница 90: ...89 Page 89 SmartFOAM NOTES...