Page
60
SmartFOAM
Figure 44: SmartFOAM Controller Unit Mounting Dimensions
CONTROLLER UNIT
The controller unit mounts in the operator panel of the
apparatus. The display is secured with four #6 pan head
screws and nuts (see
The controller requires a 2.0” (52 mm) minimum clear-
ance from the back of the operator panel to allow proper
connection of cables.
Single tank models refer to
pump harness).
❑
Connect C1 of the controller harness to the “B”
connector on the rear of the controller unit.
❑
Connect C6 of the controller harness to the “C”
connector on the rear of the controller unit.
❑
Connect C13 on the controller harness to C14 of
the pump harness.
❑
Connect C7 of the controller harness to the water
flow sensor input module.
❑
Connect C3 of the controller harness to the water
flow sensor (paddlewheel).
❑
Connect C10 of the pump harness to the low
foam sensor.
❑
C2 and C4 of the controller harness are used for
options (remote start stop and CAN communica-
tion respectively).
❑
C6, C7, C8, C15, and C16 of the pump harness
are pre-connected by Hale Products at the fac-
tory.
(shown with dual
pump harness).
❑
Connect C1 of the controller harness to the “B”
connector on the rear of the controller unit.
❑
Connect C6 of the controller harness to the “C”
connector on the rear of the controller unit.
❑
Connect C13 of the controller harness to C14 of
the (first) pump harness.
❑
Connect C14 of the 513-00074-200 controller
harness to C14 of a second pump harness, as
applicable.
❑
Connect C7 of the controller harness to the water
flow sensor input module.
❑
Connect C3 of the controller harness to the water
flow sensor (paddlewheel).
❑
Connect C8 of the pump harness to the tank A
selector.
❑
Connect C9 of the pump harness to the tank B
selector.
❑
Connect C10 of the pump harness to the tank A
low foam sensor.
❑
Connect C11 of the pump harness to the tank B
low foam sensor.
❑
C2 and C4 of the controller harness are used for
options (remote start stop and CAN communica-
tion respectively).
❑
C6, C7, C15, and C16 of the pump harness are
pre-connected by Hale Products at the factory.
Notes:
Allow a service loop on the controller unit harness con-
nections to prevent “pulling” of the wires or connectors
during body and frame flex.
Содержание MiniCAFS 2.1A
Страница 3: ...Page 2 SmartFOAM NOTES...
Страница 12: ...Page 11 SmartFOAM HALE FOAM PUMP DIMENSIONS Figure 1 1 7 and 2 1 Foam Pump Installation Envelope Dimensions...
Страница 15: ...Page 14 SmartFOAM Figure 5 Converter Installation Envelope Dimensions Located Remote for 6 5 12VDC Systems...
Страница 16: ...Page 15 SmartFOAM SYSTEM DIAGRAM Figure 6 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Страница 17: ...Page 16 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Страница 18: ...Page 17 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Страница 19: ...Page 18 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Страница 20: ...Page 19 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainers...
Страница 21: ...Page 20 SmartFOAM Figure 11 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Страница 22: ...Page 21 SmartFOAM Figure 12 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandIn lineStrainers...
Страница 23: ...Page 22 SmartFOAM Figure 13 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandFSSeries Strainers...
Страница 24: ...Page 23 SmartFOAM Figure 14 SmartFOAM Dual Pump 1 Single Tank with Valve Options and In Line Strainers...
Страница 25: ...Page 24 SmartFOAM Figure 15 SmartFOAM Dual Pump 1 Single Tank System with MST and FS Series Strainers...
Страница 26: ...Page 25 SmartFOAM Figure 16 SmartFOAM Dual Pump 1 Dual Tank System with MDT II and FS Series Strainers...
Страница 27: ...Page 26 SmartFOAM Figure 17 SmartFOAM Dual Pump 2 Single Tank System with valve options and In Line Strainers...
Страница 28: ...Page 27 SmartFOAM Figure 18 SmartFOAM Dual Pump 2 Single Tank System with MST and FS Series Strainers...
Страница 29: ...Page 28 SmartFOAM Figure 19 SmartFOAM Dual Pump 2 Dual Tank System with MDT II and FS Series Strainers...
Страница 48: ...Page 47 SmartFOAM Figure 28 Typical 4 Inch Check Valve Installation Midship Pump...
Страница 59: ...Page 58 SmartFOAM Figure 43 ADT Option Air Hose Connections Part 2...
Страница 68: ...Page 67 SmartFOAM Figure 55 Top Mount Low Level Sensor Assembly...
Страница 77: ...Page 76 SmartFOAM NOTES...
Страница 90: ...89 Page 89 SmartFOAM NOTES...