Installation Manual
Neocean IX1000 Network Storage System
Chapter 1 Product Overview
1-2
II. Rear view
(2)
(1)
(15)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(13)
(12)
(14)
(2)
(1)
(15)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(13)
(12)
(14)
(1) AC power input
(2) Power module
(hot-swappable)
(3) Serial port 1
(4) Serial port 2
(5) USB interfaces (two)
(6) Gigabit Ethernet ports 1 & 2
(7) Gigabit Ethernet ports
3 & 4
(8) 100 Mbps Ethernet port
(9) Power LED
(10) Alarm LED
(11) Positioning LED (ID LED)
(12) Reset button
(13) Power button
(14) Grounding terminal
(15) PCI-X slot (two)
Figure 1-2
The rear view of an IX1000
1.2.2 Power Module
The power module accepts AC input.
Rated voltage range: 100 VAC to 127 VAC or 200 VAC to 240 VAC; 50 Hz or 60 Hz
Max output power: 700 W
Note:
If you need a UPS, contact a H3C salesperson.
1.2.3 Heat Dissipation System
For IX1000, air comes in from the front of the chassis and gets out from the rear. The
fan is located between the disks and the main board. Air is blown onto the main board
to cool it, and exhausted from around the disks for heat dissipation.